XC
Probe Specifications
Note:
Thick wall specifications are for silicon nitride
rotors. Thin wall specifications are for zirconia rotors.
γB1 is proportional to P1/2,
so 70% of the indicated fields would be achieved at half power.
Doty
XC4 Probes Spinning Specifications |
Speeds
|
Thick
Wall
Si3N4 Rotors
|
Thin
Wall ZrO2 Rotors |
Slow
MAS |
MAS
(kHz) |
4
to 24 |
4
to 11 |
.
1 to 12 |
|
Caps
|
Thick
Long |
Thick
Short |
Thin
Long |
Thin
Short |
Volume
( μl) |
46
|
96
|
59 |
124
|
Active
Volume ( μl) |
45
|
45
|
60
|
60
|
|
XC4
Series 1H/X
RF Performance |
1H
Frequency (MHz) |
1H
power (W) |
1H γ B1 (kHz) |
Multi-X
pw90, μs |
400
WB |
240
|
130
|
2.2
|
500
WB |
300
|
130
|
2.9
|
600
WB |
270
|
120
|
3.0
|
800
NB |
200
|
110 |
4.2
|
Doty
XC5 Probes Spinning Specifications |
Speeds
|
Thick
Wall
Si3N4 Rotors |
Thin
Wall ZrO2 Rotors |
Slow
MAS |
MAS
(kHz) |
3
to 18 |
3
to 9 |
.
02 to 11 |
|
Caps
|
Thick
Long |
Thick
Short |
Thin
Long |
Thin
Short |
Volume
( μl) |
115 |
158 |
150 |
205 |
Active
Volume ( μl) |
80
|
80
|
105
|
105
|
|
XC5
Series 1H/X
RF Performance |
1H
Frequency (MHz) |
1H
power (W) |
1H γ B1 (kHz) |
Multi-X
pw90, μs |
300
WB |
300
|
120
|
2.2
|
400
WB |
300
|
120
|
2.5 |
500
WB |
280
|
120
|
2.6 |
600
WB |
260
|
110
|
2.8 |
750
NB |
250
|
110
|
4.6 |
Doty
XC7 Probes Spinning Specifications |
Rotor & Caps |
Thick
Wall
Si3N4 Rotors |
Thin
Wall ZrO2 Rotors |
Slow
MAS |
MAS
(kHz) |
2
to 12 |
2
to 7 |
.
1 to 6 |
|
Caps
|
Thick
Long |
Thick
Short |
Thin
Long |
Thin
Short |
Volume
( μl) |
241
|
455
|
299
|
564
|
Active
Volume (μl) |
211
|
211
|
262
|
262
|
|
XC7
WB Series 1H/X
RF Performance |
1H
Frequency (MHz) |
1H
power (W) |
1H γ B1 (kHz) |
Multi-X
pw90, μs |
300
WB |
350
|
120
|
2.5
|
400
WB |
300
|
110
|
3.4
|
500
WB |
250
|
90
|
4.2
|
600
WB |
210
|
80
|
5.0
|
750
WB |
170
|
70 |
6.2
|
XC
thick wall rotors
and caps are provided for fastest spinning and ease
in packing. XC thin wall rotors and caps
are available for maximum signal to noise. Long caps are provided
for highest
homogeneity
and rf field strength. Short Caps are used with XC
sealing cells .
XC "Slow
MAS" is designed
for stable spinning with tissues, liquids, and semi-solids. The XC
sample spinner easily reconfigures in just a few minutes for slow spinning
by changing the front and rear nozzle caps. All
choices of XC rotors and caps may be used with slow spin nozzle caps,
but a 50% reduction in maximum spinning speeds
should be expected for each type. The slow spinning capability may
be omitted with some cost savings, but most users will want both capabilities.
Please
contact sales with
questions or quote requests.
|